>> TSUBAKI POWER - LOCK KE Series
-
Minimum hub diameter Dn
-
When Using Hub with Guide
based on : L2 < B < 2 x
OR
-
When Using Hub without Guide
This table shows the minimum hub diameter Dn which can tolerate surface pressure P'
Minimum Hub Diameter (Dn in mm)
(Conversion)
1 MPa = 0.1020 kgf/mm2 K3 = 1.0
Model Number |
Contact pressure in the Hub Bore P' |
Yield Point of Hub Material Y.P. (MPa) Y.P. = Ò0.2 |
||||||||||
d x D Inside Dia Outside Dia |
MPa |
147 |
176 |
206 |
225 |
245 |
274 |
294 |
343 |
392 |
441 |
|
{kgf/mm2 } |
{15} |
{18} |
{21} |
{23} |
{25} |
{28} |
{30} |
{35} |
{40} |
{45} |
||
MPa |
{kgf/mm2 } |
|||||||||||
PL 005 x 016 KE |
70 |
{7.1} |
27 |
25 |
23 |
23 |
22 |
21 |
21 |
20 |
20 |
19 |
PL 006 x 017 KE |
66 |
{6.7} |
28 |
26 |
24 |
23 |
23 |
22 |
22 |
21 |
21 |
20 |
PL 008 x 021 KE |
88 |
{9.0} |
43 |
37 |
34 |
32 |
31 |
30 |
29 |
28 |
27 |
26 |
PL 010 x 023 KE |
80 |
{8.2} |
43 |
38 |
35 |
34 |
33 |
32 |
31 |
30 |
29 |
28 |
PL 011 x 024 KE |
77 |
{7.9} |
44 |
39 |
36 |
35 |
34 |
33 |
32 |
31 |
30 |
29 |
PL 012 x 026 KE |
95 |
{9.7} |
57 |
48 |
43 |
41 |
40 |
38 |
37 |
35 |
34 |
33 |
PL 014 x 028 KE |
92 |
{9.4} |
59 |
50 |
46 |
44 |
42 |
40 |
39 |
37 |
36 |
35 |
PL 015 x 029 KE |
107 |
{10.9} |
73 |
59 |
52 |
49 |
47 |
44 |
43 |
41 |
39 |
38 |
PL 016 x 030 KE |
103 |
{10.5} |
72 |
59 |
52 |
50 |
47 |
45 |
44 |
41 |
40 |
39 |
PL 017 x 031 KE |
100 |
{10.2} |
72 |
59 |
53 |
50 |
48 |
46 |
45 |
42 |
41 |
40 |
PL 018 x 032 KE |
97 |
{9.9} |
71 |
60 |
54 |
51 |
49 |
47 |
46 |
43 |
42 |
41 |
PL 019 x 033 KE |
94 |
{9.6} |
71 |
60 |
55 |
52 |
50 |
48 |
46 |
44 |
43 |
41 |
PL 020 x 038 KE |
107 |
{10.9} |
96 |
77 |
68 |
64 |
61 |
58 |
56 |
53 |
51 |
49 |
PL 022 x 040 KE |
101 |
{10.3} |
93 |
77 |
69 |
65 |
62 |
59 |
58 |
55 |
53 |
51 |
PL 024 x 042 KE |
128 |
{13.1} |
- |
106 |
88 |
81 |
76 |
70 |
68 |
63 |
60 |
57 |
PL 025 x 043 KE |
125 |
{12.8} |
- |
105 |
88 |
81 |
76 |
71 |
68 |
64 |
60 |
58 |
PL 028 x 046 KE |
117 |
{11.9} |
136 |
102 |
88 |
82 |
78 |
73 |
70 |
66 |
63 |
61 |
PL 030 x 048 KE |
124 |
{12.7} |
- |
116 |
97 |
90 |
85 |
79 |
76 |
71 |
67 |
65 |
PL 032 x 050 KE |
120 |
{12.2} |
156 |
115 |
98 |
91 |
86 |
80 |
77 |
72 |
69 |
67 |
PL 035 x 057 KE |
106 |
{10.8} |
142 |
115 |
101 |
95 |
91 |
86 |
84 |
79 |
76 |
73 |
PL 038 x 060 KE |
125 |
{12.8} |
- |
147 |
122 |
113 |
106 |
99 |
95 |
89 |
84 |
81 |
PL 040 x 062 KE |
122 |
{12.4} |
202 |
145 |
123 |
114 |
107 |
100 |
97 |
90 |
86 |
83 |
PL 042 x 064 KE |
118 |
{12.0} |
193 |
144 |
123 |
115 |
108 |
102 |
98 |
92 |
88 |
85 |
PL 045 x 064 KE |
113 |
{11.5} |
185 |
143 |
124 |
117 |
111 |
104 |
101 |
95 |
91 |
88 |
PL 048 x 070 KE |
129 |
{13.2} |
- |
179 |
147 |
135 |
126 |
117 |
113 |
105 |
99 |
95 |
PL 050 x 072 KE |
146 |
{14.9} |
- |
235 |
175 |
156 |
144 |
131 |
125 |
114 |
107 |
102 |
PL 055 x 077 KE |
137 |
{14.0} |
- |
218 |
173 |
157 |
145 |
134 |
128 |
118 |
111 |
107 |
PL 060 x 082 KE |
137 |
{14.0} |
- |
232 |
184 |
167 |
155 |
143 |
136 |
126 |
119 |
114 |
PL 065 x 087 KE |
129 |
{13.2} |
- |
222 |
183 |
168 |
157 |
146 |
140 |
130 |
123 |
118 |
PL 070 x 097 KE |
148 |
{15.1} |
- |
- |
240 |
214 |
196 |
178 |
169 |
154 |
145 |
138 |
PL 075 x 102 KE |
141 |
{14.4} |
- |
307 |
237 |
213 |
197 |
181 |
173 |
158 |
149 |
143 |
PL 080 x 107 KE |
157 |
{16.0} |
- |
- |
292 |
253 |
229 |
205 |
194 |
176 |
164 |
156 |
PL 085 x 112 KE |
150 |
{15.3} |
- |
- |
283 |
250 |
229 |
207 |
197 |
179 |
168 |
160 |
PL 090 x 123 KE |
165 |
{16.8} |
- |
- |
370 |
312 |
278 |
247 |
232 |
208 |
193 |
183 |
PL 095 x 128 KE |
158 |
{16.1} |
- |
- |
353 |
305 |
276 |
247 |
234 |
211 |
197 |
187 |
PL 100 x 133 KE |
152 |
{16.1} |
- |
- |
343 |
302 |
275 |
249 |
236 |
215 |
201 |
191 |
Note :-
- The above hub dias. do not include any safty factor. When use this table, put safty factor at customer side.
- The above hub dias, are calculated by K3 = 1.0