>> TSUBAKI POWER - LOCK KE Series
-
Minimum hub diameter Dn
This table shows the minimum hub diameter DN Which can tolerate surface pressure P' based on : B ≥ 2 x
OR
-
Minimum Hub Diameter (Dn in mm)
(Conversion)
1 MPa = 0.1020 kgf/mm2 K3 = 0.8
Model Number |
Contact pressure in the Hub Bore P' |
Yield Point of Hub Material Y.P. (MPa) Y.P. = Ò0.2 |
||||||||||
d x D Inside Dia Outside Dia |
MPa |
147 |
176 |
206 |
225 |
245 |
274 |
294 |
343 |
392 |
441 |
|
{kgf/mm2 } |
{15} |
{18} |
{21} |
{23} |
{25} |
{28} |
{30} |
{35} |
{40} |
{45} |
||
MPa |
{kgf/mm2 } |
|||||||||||
PL 005 x 016 KE |
70 |
{7.1} |
24 |
23 |
22 |
21 |
21 |
20 |
20 |
19 |
19 |
19 |
PL 006x 017 KE |
66 |
{6.7} |
25 |
24 |
23 |
22 |
22 |
21 |
21 |
20 |
20 |
20 |
PL 008 x 021 KE |
88 |
{9.0} |
36 |
33 |
31 |
30 |
29 |
28 |
27 |
26 |
26 |
25 |
PL 010 x 023 KE |
80 |
{8.2} |
37 |
34 |
32 |
31 |
31 |
30 |
29 |
28 |
28 |
27 |
PL 011 x 024 KE |
77 |
{7.9} |
38 |
35 |
33 |
32 |
32 |
31 |
30 |
29 |
29 |
28 |
PL012 x 026 KE |
95 |
{9.7} |
47 |
42 |
39 |
37 |
36 |
35 |
34 |
33 |
32 |
31 |
PL014 x 028 KE |
92 |
{9.4} |
49 |
44 |
41 |
40 |
39 |
37 |
37 |
35 |
34 |
34 |
PL 015 x 029 KE |
107 |
{10.9} |
57 |
50 |
46 |
44 |
42 |
41 |
40 |
38 |
37 |
36 |
PL 016 x 030 KE |
103 |
{10.5} |
57 |
50 |
46 |
44 |
43 |
41 |
41 |
39 |
38 |
37 |
PL 017 x 031 KE |
100 |
{10.2} |
58 |
51 |
47 |
45 |
44 |
42 |
41 |
40 |
39 |
38 |
PL 018 x 032 KE |
97 |
{9.9} |
58 |
52 |
48 |
46 |
45 |
43 |
42 |
41 |
40 |
39 |
PL 019 x 033 KE |
94 |
{9.6} |
59 |
53 |
49 |
47 |
46 |
44 |
43 |
42 |
41 |
40 |
PL 020 x 038 KE |
107 |
{10.9} |
74 |
65 |
60 |
57 |
55 |
53 |
52 |
50 |
48 |
47 |
PL 022 x 040 KE |
101 |
{10.3} |
75 |
66 |
61 |
59 |
57 |
55 |
54 |
51 |
50 |
49 |
PL 024 x 042 KE |
128 |
{13.1} |
- |
82 |
73 |
69 |
66 |
63 |
61 |
58 |
55 |
54 |
PL 025 x 043 KE |
125 |
{12.8} |
- |
83 |
74 |
70 |
67 |
64 |
62 |
59 |
56 |
55 |
PL 028 x 046 KE |
117 |
{11.9} |
98 |
83 |
76 |
72 |
69 |
66 |
64 |
61 |
59 |
58 |
PL 030 x 048 KE |
124 |
{12.7} |
- |
91 |
82 |
78 |
74 |
71 |
69 |
65 |
63 |
61 |
PL 032 x 050 KE |
120 |
{12.2} |
109 |
92 |
83 |
79 |
76 |
72 |
71 |
67 |
65 |
63 |
PL 035 x 057 KE |
106 |
{10.8} |
110 |
97 |
89 |
85 |
82 |
79 |
77 |
74 |
71 |
70 |
PL 038 x 060 KE |
125 |
{12.8} |
- |
115 |
103 |
97 |
93 |
89 |
86 |
82 |
78 |
76 |
PL 040 x 062 KE |
122 |
{12.4} |
138 |
116 |
104 |
99 |
95 |
90 |
88 |
83 |
80 |
78 |
PL 042 x 064 KE |
118 |
{12.0} |
137 |
117 |
105 |
100 |
96 |
92 |
90 |
85 |
82 |
80 |
PL 045 x 067 KE |
113 |
{11.5} |
137 |
118 |
108 |
103 |
99 |
95 |
92 |
88 |
85 |
83 |
PL 048 x 070 KE |
129 |
{13.2} |
- |
138 |
122 |
115 |
110 |
105 |
102 |
92 |
92 |
89 |
PL 050 x 072 KE |
146 |
{14.9} |
- |
160 |
138 |
128 |
121 |
114 |
110 |
103 |
98 |
95 |
PL 055 x 077KE |
137 |
{14.0} |
- |
160 |
140 |
132 |
125 |
118 |
114 |
108 |
103 |
100 |
PL 060 x 082 KE |
137 |
{14.0} |
- |
170 |
149 |
140 |
133 |
126 |
112 |
115 |
110 |
106 |
PL 065 x 087 KE |
129 |
{13.2} |
- |
171 |
152 |
143 |
137 |
130 |
126 |
119 |
115 |
111 |
PL 070 x 097 KE |
148 |
{15.1} |
- |
- |
157 |
174 |
165 |
154 |
149 |
140 |
133 |
128 |
PL 075 x 102 KE |
141 |
{14.4} |
- |
218 |
189 |
177 |
168 |
158 |
153 |
144 |
138 |
133 |
PL 080 x 107 KE |
157 |
{16.0} |
- |
- |
218 |
201 |
189 |
176 |
169 |
158 |
150 |
144 |
PL 085 x 112 KE |
150 |
{15.3} |
- |
- |
219 |
203 |
192 |
179 |
173 |
162 |
154 |
149 |
PL 090 x 123 KE |
165 |
{16.8} |
- |
- |
263 |
241 |
225 |
208 |
200 |
185 |
175 |
168 |
PL 095 x 128 KE |
158 |
{16.1} |
- |
- |
262 |
242 |
227 |
211 |
203 |
189 |
179 |
172 |
PL 095 x 133 KE |
152 |
{15.5} |
- |
- |
263 |
244 |
230 |
215 |
207 |
193 |
184 |
177 |
Note :-
- The above hub dias. do not include any safty factor. When use this table, put safty factor at customer side.
- The above hub dias, are calculated by K3 = 0.8