>> TSUBAKI POWER - LOCK TF Series
-
Minimum hub diameter Dn
-
When Using Hub with Guide
based on : 1 <= B < 2 x
OR
-
When Using Hub without Guide
based on : 1 <= B < 2 x
This table shows the minimum hub diameter Dn which can tolerate surface pressure P'
Minimum Hub Diameter (Dn in mm)
(Conversion)
1 MPa = 0.1020 kgf/mm2 K3 = 1.0
Model Number |
Contact pressure in the Hub Bore P' |
Yield Point of Hub Material Y.P. (MPa) Y.P. = Ò0.2 |
||||||||||
d x D Inside Dia Outside Dia |
MPa |
147 |
176 |
206 |
225 |
245 |
274 |
294 |
343 |
392 |
441 |
|
{kgf/mm2 } |
{15} |
{18} |
{21} |
{23} |
{25} |
{28} |
{30} |
{35} |
{40} |
{45} |
||
MPa |
{kgf/mm2 } |
|||||||||||
PL 006 x 012 TF |
93 |
{9.5} |
26 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
25 |
PL 008 x 015 TF |
107 |
{10.9} |
38 |
31 |
27 |
27 |
27 |
27 |
27 |
27 |
27 |
27 |
PL 010 x 018 TF |
102 |
{10.4} |
43 |
35 |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
PL 011 x 018 TF |
102 |
{10.4} |
43 |
35 |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
32 |
PL 012 x 020 TF |
92 |
{9.3} |
42 |
36 |
34 |
34 |
34 |
34 |
34 |
34 |
34 |
34 |
PL 014 x 022 TF |
83 |
{8.5} |
42 |
38 |
38 |
38 |
38 |
38 |
38 |
38 |
38 |
38 |
PL 015 x 023 TF |
130 |
{13.3} |
94 |
60 |
49 |
45 |
42 |
39 |
39 |
39 |
39 |
39 |
PL 016 x 024 TF |
125 |
{12.7} |
84 |
58 |
49 |
45 |
43 |
40 |
40 |
40 |
40 |
40 |
PL 018 x 026 TF |
126 |
{12.9} |
95 |
64 |
54 |
49 |
47 |
47 |
47 |
47 |
47 |
47 |
PL 019 x 027 TF |
122 |
{12.4} |
88 |
63 |
54 |
50 |
49 |
49 |
49 |
49 |
49 |
49 |
PL 020 x 028 TF |
118 |
{12.0} |
84 |
63 |
54 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
PL 022 x 032 TF |
74 |
{7.5} |
56 |
54 |
54 |
54 |
54 |
54 |
54 |
54 |
54 |
54 |
PL 024 x 034 TF |
70 |
{7.1} |
57 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
PL 025 x 034 TF |
70 |
{7.1} |
57 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
56 |
PL 028 x 039 TF |
91 |
{9.3} |
81 |
69 |
63 |
61 |
61 |
61 |
61 |
61 |
61 |
61 |
PL 030 x 041 TF |
86 |
{8.8} |
81 |
71 |
65 |
62 |
62 |
62 |
62 |
62 |
62 |
62 |
PL 032 x 043 TF |
82 |
{8.4} |
82 |
72 |
66 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
PL 035 x 047 TF |
78 |
{8.0} |
86 |
76 |
71 |
69 |
69 |
69 |
69 |
69 |
69 |
69 |
PL 038 x 050 TF |
74 |
{7.5} |
87 |
79 |
73 |
72 |
72 |
72 |
72 |
72 |
72 |
72 |
PL 040 x 053 TF |
70 |
{7.1} |
89 |
81 |
76 |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
PL 042 x 055 TF |
68 |
{6.9} |
91 |
83 |
78 |
78 |
78 |
78 |
78 |
78 |
78 |
78 |
PL 045 x 059 TF |
82 |
{8.4} |
112 |
98 |
91 |
87 |
86 |
86 |
86 |
86 |
86 |
86 |
PL 048 x 062 TF |
78 |
{8.0} |
113 |
100 |
93 |
90 |
87 |
87 |
87 |
87 |
87 |
87 |
PL 050 x 065 TF |
74 |
{7.6} |
114 |
103 |
96 |
92 |
92 |
92 |
92 |
92 |
92 |
92 |
PL 055 x 071 TF |
63 |
{6.4} |
113 |
104 |
98 |
98 |
98 |
98 |
98 |
98 |
98 |
98 |
PL 060 x 077 TF |
58 |
{5.9} |
117 |
109 |
104 |
104 |
104 |
104 |
104 |
104 |
104 |
104 |
PL 065 x 084 TF |
53 |
{5.4} |
123 |
115 |
111 |
111 |
111 |
111 |
111 |
111 |
111 |
111 |
PL 070 x 090 TF |
67 |
{6.8} |
147 |
134 |
126 |
123 |
120 |
119 |
119 |
119 |
119 |
119 |
PL 075 x 095 TF |
63 |
{6.4} |
151 |
139 |
131 |
127 |
126 |
126 |
126 |
126 |
126 |
126 |
PL 080 x 100 TF |
79 |
{8.1} |
185 |
164 |
151 |
145 |
141 |
136 |
133 |
131 |
131 |
131 |
PL 085 x 106 TF |
75 |
{7.7} |
188 |
168 |
156 |
151 |
146 |
141 |
138 |
137 |
137 |
137 |
PL 090 x 112 TF |
72 |
{7.3} |
191 |
173 |
161 |
156 |
152 |
147 |
144 |
144 |
144 |
144 |
Note :-
- The above hub dias. do not include any safty factor. When use this table, put safty factor at customer side.
- The above hub dias, are calculated by K3 = 0.8