>> TSUBAKI POWER - LOCK AS Series

Minimum hub diameter Dn


When Using One POWER-LOCK


Suggested outside hub diameter for two or more POWER-LOCK.
This table shows the minimum hub diameter Dn
Which can tolerate surface pressure P' based on :
B ≥ ( Z x Lt) + Lt Z : Number of POWER-LOCK (2 ≤ Z ≤4)
* The value, d/2 or more, is to be suggested as the guide length C.


Minimum Hub Diameter (Dn in mm) (Conversion)


1MPa = 0.1020 kgf/mm2             K3 = 0.6

Model Number
Contact Pressure in the Hub Bore
P'
Yield Point of Hub Material Y.P. (MPa) Y.P. = Ó0.2
d                x      D
Inside Dia    Outside Dia
MPa
147
176
206
225
245
274
294
343
392
441
{kgf/mm2}
{15}
{18}
{21}
{23}
{25}
{28}
{30}
{35}
{40}
{45}
MPa
{kgf/mm2}
PL 019 x 047
85
{8.7}
78
71
67
65
63
61
60
58
57
55
PL 020 x 047
85
{8.7}
78
71
67
65
63
61
60
58
57
55
PL 022 x 047
85
{8.7}
78
71
67
65
63
61
60
58
57
55
PL 024 x 050
101
{10.3}
93
82
76
73
71
68
67
64
62
61
PL 025 x 050
101
{ 10.3}
93
82
76
73
71
68
67
64
62
61
PL 028 x 055
92
{9.4}
96
86
80
78
76
73
72
69
67
66
PL 030 x 055
92
{9.4}
96
86
80
78
76
73
72
69
67
66
PL 032 x 060
106
{10.8}
116
102
93
90
86
83
81
78
75
73
PL 035 x 060
106
{10.8}
116
102
93
90
86
83
81
78
75
73
PL 038 x 065
107
{10.9}
127
111
102
97
94
90
88
84
82
80
PL 040 x 065
107
{10.9}
127
111
102
97
94
90
88
84
82
80
PL 042 x 075
121
{12.3}
165
139
125
119
114
109
106
101
97
94
PL 045 x 075
121
{12.3}
165
139
125
119
114
109
106
101
97
94
PL 048 x 080
113
{11.5}
164
141
128
123
118
113
110
105
102
99
PL 050 x 080
113
{11.5}
164
141
128
123
118
113
110
105
102
99
PL 055 x 085
130
{13.3}
207
168
149
141
134
127
124
117
112
109
PL 060 x 090
123
{12.5}
202
169
152
144
138
131
128
121
117
113
PL 065 x 095
126
{12.9}
221
183
163
154
148
140
136
129
124
120
PL 070 x 110
133
{13.6}
276
222
196
184
176
166
161
152
146
141
PL 075 x 115
127
{13.0}
271
223
198
188
180
170
166
157
151
146
PL 080 x 120
123
{12.5}
269
225
202
192
184
175
170
161
155
151
PL 085 x 125
128
{13.1}
297
244
217
205
194
186
180
171
164
159
PL 090 x 130
123
{12.6}
294
245
220
208
200
190
185
175
169
164
PL 095 x 135
129
{13.2}
324
265
235
222
212
201
195
185
177
172
PL 100 x 145
127
{13.0}
341
281
250
237
226
215
209
197
190
184
PL 110 x 155
120
{12.2}
337
285
257
244
235
223
218
207
199
194
PL 120 x 165
123
{12.5}
369
309
277
263
252
240
234
222
213
207
PL 130 x 180
120
{12.2}
392
331
298
284
272
259
253
240
231
225
PL 140 x 190
121
{12.3}
417
351
316
301
288
275
268
254
245
238
PL 150 x 200
129
{13.2}
480
392
348
329
314
298
289
274
263
254
PL 160 x 210
129
{13.2}
504
412
366
345
330
313
304
287
276
267
PL 170 x 225
119
{12.1}
485
411
371
353
339
323
315
299
288
280
PL 180 x 235
121
{12.3}
516
435
391
372
357
340
331
314
303
294
PL 190 x 250
112
{11.4}
507
437
399
381
367
351
343
327
316
307
PL 200 x 260
113
{11.5}
532
458
416
398
383
366
357
341
329
320
PL 220 x 285
115
{11.7}
593
508
461
439
423
404
394
375
362
352
PL 240 x 305
120
{12.2}
663
560
505
480
461
439
428
407
392
381
PL 260 x 325
129
{13.2}
780
637
566
534
510
484
470
444
426
413
PL 280 x 355
114
{11.6}
732
628
571
545
525
501
489
466
450
438
PL 300 x 375
118
{12.0}
801
680
615
585
563
537
523
497
479
466

Note :-

  1. The above hub dias. do not include any safty factor. When use this table, put safty factor at customer side.
  2. The above hub dias. are calculated by K3  =0.8.
1    2    3

Back